COMPARISON OF LOW AND HIGH FREQUENCY FATIGUE TESTS - Production Enginnering Archives

Lorem ipsum dolor sit amet, consectetur ad elit.
Morbi tincidunt libero ac ante accumsan.
Go to content

Alan Vaško, Juraj Belan, Lenka Kuchariková
COMPARISON OF LOW AND HIGH FREQUENCY FATIGUE TESTS
PRODUCTION ENGINEERING ARCHIVES 17(2017), pp. 14-17
DOI: 10.30657/pea.2017.17.03

Abstract
The paper presents the results of low and high frequency fatigue tests carried out on nodular cast iron. The specimens of synthetic nodular cast irons from three different melts were studied in the high cycle fatigue region (from 105 to 108 cycles) using fatigue experimental equipments for low and high frequency cyclic loading. Low frequency fatigue tests were carried out at frequency f  120 Hz using the fatigue experimental machine Zwick/Roell Amsler 150HFP 5100; high frequency fatigue tests were carried out at frequency f  20 kHz using the ultrasonic fatigue testing device KAUP-ZU. Both fatigue tests were realised at sinusoidal cyclic push-pull loading (stress ratio R = –1) at ambient tem-perature (T = 20  5 °C).



Keywords
fatigue test
low frequency cyclic loading
high frequency cyclic loading
nodular cast iron
Alan Vaško ORCID:
Juraj Belan ORCID: 0000-0002-2428-244X
Lenka Kuchariková ORCID: 0000-0002-2688-1075



Back to content